Spend £60 for FREE Delivery
Low Price Promise
Fully Stocked UK Warehouse
Trusted by the trade
Friendly Knowledgeable Team
No Quibble Returns
View All Spa Packs, Panels & Spares Articles

Spa & Hot Tub Error Codes

Spas & Hot Tubs with digital displays can give error code for most equipment within the spa when an issue accures. 
Some spa error codes can be somewhat cryptic, therefore we have put together a list of hot tub error codes and meanings blow which covers all the major manufactures of spa controls.

Balboa Error Codes

  • pd: Power supply on battery
  • OH: Sensors reading 112-118F
  • OHH: Overheat. One sensor has detected 118º. Spa has shut down.
  • OHS: Overheat.. One sensor has detected 110º. Spa has shut down.
  • Flo: flow/pressure switch error
  • Cool: Water temp 20 degrees below set point
  • ICE: Potential freeze condition
  • Sn1: Hi-limit sensor failure
  • Sn3: Temp sensor malfunction
  • Sna: Sensor A fail
  • Snb: Sensor B fail
  • SnS: Sensors out of balance. If alternating with temp, may be temporary condition.
  • HFL: Substantial difference between temp sensors detected. Could indicate a flow problem
  • LF: Persistent low flow problems. (Displays on the 5th occurrence of "HFL" message with 24 hours). Heater is shut down, but other spa functions run normally.
  • dr: Inadequate flow in heater.
  • dry: Inadequate flow in heater. (Displays on third occurrence of "dr" message)
  • Pr: When spa is first actuated, it will go into Priming Mode
  • ---: Unknown water temp.
  • Std: Spa operating in Standard Mode.
  • Ecn: Spa operating in Economy Mode.
  • SE: Spa operating in Standard-in-Economy Mode.
  • ILOC: Interlock failure - possible pump/ozone spike

Applied Computer Controls (ACC)

  • CoLd : Temp in heater housing is below 40° F. Low speed / circ pump will operate continuously until the temp rises above 45° F.
  • OH : Overheat. Spa temp over 108°. 
  • HLoH : Hi Limit Over Heat. Hi limit sensor is disconnected, shorted, or spa temp is above 112° F.
  • SEoP : Sensor open or disconnected. Heater disabled but spa operational.
  • SESH : Sensor short, nonfunctional. Heater disabled but spa operational.
  • PSoC : Pressure switch open with circulation pump. 
  • PSoL : Pressure switch open with low pump. 
  • PSoH : Pressure switch open with high pump. 
  • ToE : Time out error. Rare system error.

Brett Aqualine Error Codes

  • OH: Temp exceeds 118 F
  • Fr: Freeze condition - temp below 40 degrees
  • FL: Pressure switch failure
  • EO: Shorted temp sensor
  • E1: Open temp sensor
  • E2: Shorted hi-limit sensor
  • E3: Open hi-limit sensor
  • E4: Shorted flow switch
  • E7: Improper electrical connection

CTI Error Codes

  • thl/39: temp probe problem
  • th2/current temp: temp probe problem
  • th3/39: water temp below 39° F
  • OH: water over 112° F. System will restart when temp. drops
  • hot: water over 112° F. System will restart when temp. drops
  • HL: High limit switch tripped

Dream Maker Error Codes

  • OH: Overheat 108° F, spa is deactivated.
  • FL: Flow. Pressure switch not working
  • SN: Non functional high temperature sensor. Heater is deactivated
  • F2: 4 hours daily filtration
  • F4: 8 hours daily filtration
  • F6 : 12 hours daily filtration
  • FC : continuous filtration

EasyPak Error Codes

  • C: Celsius
  • CL: Current Time of Day
  • ECdu: Econo Mode Duration
  • Econ: Econo Mode Turn On
  • F: Fahrenheit
  • Fldu: Filter Cycle Duration
  • Flon: Filter Cycle Turn On
  • FLC: Pressure Switch Alarm
  • FLO: Pressure Switch Alarm
  • FrEE: Freeze Protection Alarm
  • HL: High Temperature Alarm
  • Loc: Panel / Keypad Locked
  • PrH: Temperature Sensors Alarm
  • Prr: Temperature Sensors Alarm
  • Tu: Temp Set Celsius
  • Tu: Temp Set F

Gecko

  • AOH: Temp in Equipment compartment to high
  • FLO: Pressure switch failure, switch open
  • FLC: Pressure switch failure, switch closed
  • FrE: Possible freeze condition
  • Flashing Display
  • 3 Flashing Dots
  • 3 Flashing Dots & LED
  • HL: Sensor measuring 119F
  • Prr: Temp sensor failure
  • Prh: Hi-limit sensor failure

Gecko SP Codes (Spa Packs)

  • SP-HR: hardware error
  • SP-BR: breaker setting to low
  • SP-IN: Input voltage low
  • SP-F1,F2 or F3: Fuse 1,2 or blown
  • SP-OT: Temp inside skirt high
  • SP-OH: Water temp over 112F

Gecko RH Codes (Heater)

  • RH-HR: Heater Hardware error
  • RH-NH: Heat attempted & failed
  • RH-NF: No flow in heater
  • RH-NC: Comm error to Pack
  • RH-HL: Heater Hi Limit

Gecko Accessory Codes

  • P1, P2 or P3-ER: Pump 1,2 or 3 failure
  • CP-ER: Circ pump failure
  • BL-ER: Blower failure
  • O3-Er: Ozone error
  • A1/A2-ER: Aux. system error
  • FN-ER: Fan failure
  • FB-ER: Fiber optic failure
  • SC-ER: System learning failure

Hercules Error Codes

  • OH: Spa temp exceeds acceptablelimits
  • FLO: Flow problem
  • ICE: Freeze condition detected
  • SN1: Hi-limit sensor failure
  • SN2: Temp sensor failure

Hurricane Error Codes

  • PS: Flow/pressure switch fail
  • SH: Shorted sensor
  • OP: Open Sensor Degrees
  • LO: Temp below 60 degrees
  • HL: Temp above 118 degrees
  • OH: Spa temp exceeds limits
  • FLO: Flow problem
  • ICE: Freeze condition detected
  • SN1: Hi-limit sensor failure
  • SN2: Temp sensor failure

Hurricane Error Codes

  • C: Celsius
  • CL: Current Time of Day
  • ECdu: Economy Mode Duration
  • Econ: Economy Mode Turn On
  • F: Fahrenheit
  • Fldu: Filter Cycle Duration
  • Flon: Filter Cycle Turn On
  • FLC: Pressure Switch Alarm
  • FLO: Pressure Switch Alarm
  • FrEE: Freeze Protection Alarm
  • HL: High Temp Alarm
  • Loc: Panel / Keypad Locked
  • PrH: Temperature Sensors Alarm
  • Prr: Temperature Sensors Alarm
  • Tu:  Temperature Set Celsius
  • Tu: Temperature Set Fahrenheit

Jacuzzi Error Codes

  • OH : Overheat Protection (Heater is deactivated, pumps low speed is activated)
  • COOL : temp 20° F cooler than set point
  • FLO* : Flow Switch (heater is deactivated. Pump may also be deactivated)
  • FLO2 : Closed or shorted flow switch on system startup
  • Hold : Panel pressed too many times in a short period of time
  • HOT : Circuit Board temp exceeded acceptable limit
  • ICE : Freeze protection.No action is necessary
  • I CE2 : Freeze protection.No action is necessary
  • PnL : Communication error between the panel and circuit board
  • ---- : "Watchdog" problem detected
  • Sn1 : Open/Shorted sensor
  • Sn3 : Open /shorted sensor FLO2: Closed/shorted flow switch at startup

Pinnacle Spas Error Codes

  • OH: Temperature has exceeded 110° F
  • SN: Sensor failure
  • FL: Flow/pressure switch stuck in closed position

Spa Builders Support Error Codes

  • Sn1: Nonfunctional high temp sensor.
  • Sn2: Nonfunctional temp sensor.
  • FL1: Water flow problem, pressure switch malfunction. Check for low water level and ensure pump is primed. Check for clogged filter
  • FL2: Pressure switch problem. Switch closed while pump is deactivated
  • COL: Cool condition. If water temp drops 20ºF below set temp, low speed pump and heater activates to bring temp within 15º of set temp
  • ICE: Freeze condition. 55ºF detected. Low speed pump and heater will activate until spa reaches 65ºF
  • OH: High temperature condition, has reached 110ºF. Low speed pump (and air blower if equipped) will activate to lower temp
  • ---: "Watchdog". Water temp has reached 118ºF.

Spa Quip Error Codes

  • err 1 (H20) : Prime Failed
  • err 3: Stuck Button
  • err 4 : No Water Sensor
  • err 5 : Over temp
  • err 6 : Thermal Cut Out Tripped
  • err 7 : Stuck Relay
  • err 8 : No Temp Data
  • 01: Stuck Button
  • 02: No Controller Data
  • 03: Temp Sensor
  • 04: Water Sensor
  • 05: Spa Over Temp
  • 06: Heater Thermal Cut Out
  • 07: Stuck Heater Relay
  • 09: Water Prime Failed

Sundance Spas Error Codes

  • COL: Temp 20F below set point
  • ILOC: Interlock failure - possible pump/ozone spike
  • FLO/FL1/FL2: Flow/Pressure switch malfunction
  • Hold: Panel buttons pressed to many times/quickly
  • HOT: PCB temperature above acceptable limit - air blower on
  • ICE: Potential freeze condition
  • Pnl: Communication between PCB and panel interrupted
  • Sn1: Hi-limit sensor failure
  • Sn3: Temp sensor failure
  • ---: "Watchdog" problem detected (possible temp /hi-limit error)

Vita Spas Error Codes

  • HiLi: Water tem over acceptable limit
  • BJ2P: Pump/Blower purge - normal condition
  • FP: Freeze protect mode - temp under acceptable condition
  • SS=0;SS=S;LS=O;LS=S : Multiple causes; open sensors, bad connection or voltage

Flashing Light Error Codes 


1 flash - 3 second gap High Limit fault
2 flashes - 3 second gap Pressure/Flow switch short circuit
3 flashes - 3 second gap Pressure/Flow switch open circuit
4 flashes - 3 second gap Open circuit Sensor(s)
Flash - 1 second on, 1 second off Same as OH
Flash - briefly OFF once per second Same as Sn1 or Sn3
Flash - briefly ON once per second Same as FLC
Blinking Power Indicator Light - Hydromate High Limit tripped or, sensor fault
1 flash per second - onga 4352,
53, 95, etc
Pressure switch open circuit - could also be motor, or motor thermal overload
3 flashes per second - onga 4352,
53, 95, etc
Electronic fault - sensor (most common cause) or PCB
Green flashes - Spaquip Pulsar/2095 series Water sensor fault - lack of water
Red/Green alternate flashes Temperature sensor fault, open circuit, or high limit tripped - push Reset Rod



 
warning
Confirm add to basket
Return to listing
Add to basket
COMPARISON BASKET
COMPARE